Quick Links


Register

Detectors

Bild

Produkt

Beschreibung

WFD-OA05
Addressable Optical Smoke Detector 24VDC
- Photoelectric scattering (Tyndall effect)
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7 Ed2000
- CE certified according to CPD
- Cable section max 2,5mm²
- 8 levels sensitivity setting (0,1 dB/m to 0,35 dB/m)
- Base isolator (option)
- Base relay (option)
- Constant sensitivity thanks to auto correction
- Security addressing
WFD-TA05
Addressable Fixed / Rate of Rise Heat Detector 24VDC
- Fixed / Rate of Rise Heat Detector
- 1 remote alarm indicator output
- Lockable
- Standard EN54-5
- CE certified according to CPD
- Cable section max 2,5mm²
- 6 levels sensitivity setting (62°C to 75°C)
- Base isolator (option)
- Base relay (option)
- Security addressing
WFD-MA05
Addressable Optical Smoke / Heat Detector 24VDC
- Photoelectric scattering (Tyndall effect)
- Optical element made sensitive by thermal element
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7 Ed2000
- CE certified according to CPD
- Cable section max 2,5mm²
- 8 levels sensitivity setting (0,1 dB/m to 0,35 dB/m)
- Base isolator (option)
- Base relay (option)
- Constant sensitivity thanks to auto correction
- Security addressing
WFD-OC05
Conventional Optical Smoke Detector 24VDC
- Photoelectric scattering (Tyndall effect)
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7 Ed2000
- CE certified according to CPD
- Cable section max 2,5mm²
WFD-TRC05
Conventional Fixed / Rate of Rise Heat Detector 24VDC
- Fixed / Rate of Rise Heat Detector
- 1 remote alarm indicator output
- Lockable
- Standard EN54-5
- CE certified according to CPD
- Cable section max 2,5mm²
WFD-OC05.12
Optical Smoke Detector 12VDC for Security Application
- Photoelectric scattering (Tyndall effect)
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7 Ed2000
- CE certified according to CPD
- Cable section max 2,5mm²
- 12VDC
WFD-TRC05.12
Conventional Fixed / Rate of Rise Heat Detector 12VDC for Security Application
- Fixed / Rate of Rise Heat Detector
- 1 remote alarm indicator output
- Lockable
- Standard EN54-5
- CE certified according to CPD
- Cable section max 2,5mm²
- 12VDC

Linear Smoke Beam Detectors

Bild

Produkt

Beschreibung

WFD-DLFB-A
Addressable Linear Smoke Beam Detector
- Up to 100m coverage and 14m wide
coverage (7m on each side )
- Standard EN54-12
- CE certified according to CPD
- No external power supply needed
- Small and streamlined size
- Easy mounting and setting
- Visible ray to help alignment
WFD-DLFB-C
Conventional Linear Smoke Beam Detector
- Up to 100m coverage and 14m wide
coverage (7m on each side )
- Standard EN54-12
- CE certified according to CPD
- No external power supply needed
- Small and streamlined size
- Easy mounting and setting
- Visible ray to help alignment
WFD-DLFB-R
Relay Linear Smoke Beam Detector
- Up to 100m coverage and 14m wide
coverage (7m on each side )
- Standard EN54-12
- CE certified according to CPD
- Small and streamlined size
- Easy mounting and setting
- Visible ray to help alignment